首页| 行业标准| 论文文档| 电子资料| 图纸模型
购买积分 购买会员 激活码充值

您现在的位置是:团子下载站 > 其他 > Selection and Rating of Transf

Selection and Rating of Transf

  • 资源大小:333
  • 上传时间:2022-01-04
  • 下载次数:0次
  • 浏览次数:30次
  • 资源积分:1积分
  • 标      签: Transf

资 源 简 介

SelecTIon and RaTIng of Transformers A). IntroducTIon The number of non-linear loads – which draw non-sinusoidal currents even if fed with sinusoidal voltage -connected to the power supply system is large and is conTInuing to grow rapidly. These currents can bedefined in terms of a fundamental component and harmonic components of higher order.In power transformers the main consequence of harmonic currents is an increase in losses, mainly inwindings, because of the deformation of the leakage fields. Higher losses mean that more heat is generatedin the transformer so that the operating temperature increases, leading to deterioration of the insulationand a potential reduction in lifetime. As a result, it is necessary to reduce the maximum power load on the transformer, a practice referred to asde-rating, or to take extra care in the design of the transformer to reduce these losses.To estimate the de-rating of the transformer, the load’s K-factor may be used. This factor is calculatedaccording to the harmonic spectrum of the load current and is an indication of the additional eddy currentload losses. It reflects the excess losses experienced in a traditional wire wound transformer.Modern transformers use alternative winding designs such as foil windings or mixed wire/foil windings. B). Transformer losses Transformer losses consists of no-load (or core loss) and load losses. This can be expressed by the equationbelow.  where:PC = core or no-load loss,PLL = load lossPT = total loss.Core or no-load loss is due to the voltage excitation of the core. Although the magnetizing current doesinclude harmonics, these are extremely small compared with the load current and their effect on the lossesis minimal. Load losses are made up of I² R loss, eddy current loss and stray loss, or in equation form:  Where:I²R = loss due to load current and DC resistance of the windingsPEC = winding eddy current lossPSL = stray losses in clamps, tanks, etc. The I²R loss is due to the current flowing in the resistance of the windings. It is also called ohmic loss ordc ohmic loss. The ohmic loss is proportional to the square of the magnitude of the load current,including the harmonic components, but is independent of the frequency. It is determined by measuringthe dc resistance and calculating the resulting loss using the winding currents at full load.There are no test methods available to determine individual winding eddy current loss or to separatetransformer stray loss from eddy current loss. Instead, the total stray and eddy current loss is determinedby determining the total load loss and subtracting the calculated ohmic losses, i.e., The eddy current loss is assumed to vary with the square of the rms current and the square of the frequency(harmonic order h), i.e.,
VIP VIP