首页| 行业标准| 论文文档| 电子资料| 图纸模型
购买积分 购买会员 激活码充值

您现在的位置是:团子下载站 > 其他 > AD8494/AD8495/AD8496/AD849,pdf

AD8494/AD8495/AD8496/AD849,pdf

  • 资源大小:433
  • 上传时间:2021-11-29
  • 下载次数:0次
  • 浏览次数:26次
  • 资源积分:1积分
  • 标      签: Amplifier 温度传感器

资 源 简 介

The AD8494/AD8495/AD8496/AD8497 are precision instrumentaTIon amplifiers with thermocouple cold juncTIon compensators on an integrated circuit. They produce a high level (5 mV/°C) output directly from a thermocouple signal by combining an ice point reference with a precalibrated amplifier. They can be used as standalone thermometers or as switched output setpoint controllers using either a fixed or remote setpoint control. The AD8494/AD8495/AD8496/AD8497 can be powered from a single-ended supply (less than 3 V) and can measure temperatures below 0°C by offsetTIng the reference input. To minimize self-heaTIng, an unloaded AD849x typically operates with a total supply current of 180 μA, but it is also capable of delivering in excess of ±5 mA to a load. The AD8494 and AD8496 are precalibrated by laser wafer trimming to match the characteristics of J type (iron-constantan) thermocouples; the AD8495 and AD8497 are laser trimmed to match the characteristics of K type (chromel-alumel) thermo-couples. See Table 1 on the data sheet for the optimized ambient temperature range of each part. The AD8494/AD8495/AD8496/AD8497 allow a wide variety of supply voltages. With a 5 V single supply, the 5 mV/°C output allows the devices to cover nearly 1000 degrees of a thermo-couple’s temperature range. The AD8494/AD8495/AD8496/AD8497 work with 3 V supplies, allowing them to interface directly to lower supply ADCs. They can also work with supplies as large as 36 V in industrial systems that require a wide common-mode input range. Product Highlights Complete, precision laser wafer trimmed thermocouple signal conditioning system in a single IC package. Flexible pinout provides for operation as a setpoint controller or as a standalone Celsius thermometer. Rugged inputs withstand 4 kV ESD and provide over-voltage protection (OVP) up to VS ± 25 V. Differential inputs reject common-mode noise on the thermocouple leads. Reference pin voltage can be offset to measure 0°C on single supplies. Available in a small, 8-lead MSOP that is fully RoHS compliant. Applications K type thermocouple temperature measurement Setpoint controller Celsius thermometer Universal cold junction compensator White goods (oven, stove top) temperature measurements Exhaust gas temperature sensing Catalytic converter temperature sensing
VIP VIP